Ice cores were taken with a 9 cm inner diameter Kovacs ice corer. Ice cores were melted at 4 deg C with added filtered seawater (100 ml per 1 cm core section). Total volume of the melted sample was measured, the sample gently mixed, and 100 ml filled in brown glass bottles and preserved with 1 ml GAA Lugol for protist analysis. The remaining volume was sieved over 64 um (note: 20 um sieve requested in protocol was not available), rinsed into vials with a squeeze bottle and preserved in ~2-4% Zoofix for meiofauna analysis. Protocol 15.5.7 from Sampling protocol version 1 was used, except that sections 0-1 and 1-3 cm were combined into one since 0-1 cm was impossible to saw in the melting conditions we experienced.
pi_email: bodil.bluhm@uit.no projectID: The Nansen Legacy (RCN#276730) pi_address: Hansine Hansens veg 18, 9037 Langnes Tromsø
recordedBy: Bodil Bluhm pi_institution: UiT - The Arctic University of Norway
RF3 T3-1-1, 0 cm = ice-water interface
2018-11-05T09:46:59Z: Initial read in of the log files.
2018-11-05T16:09:59Z: Rewriting wrongly inherited fields
2018-11-07T12:52:41Z: Updated station names
2021-08-12T08:46:47Z: Standardising PI email and institutions